(718) 838-8187 info@momentum-dc.com 15 Tuve Ln, S. Hackensack, NJ 07606
Building Momentum, Ensuring Compliance.
MOMENTUMENGINEERING CONSULTANT, PLLC
Momentum Engineering · NYC & NJ

Suspended Scaffold Design (CD-5)

Sealed suspended scaffold designs, calculations and CD-5 filing packages for facade restoration, FISP repairs and window work across New York City, so your rigger can mobilize safely and on schedule.

Suspended Scaffold Design (CD-5) by Momentum Engineering Consultant in New York City
Related ResourcesDOB Suspended Scaffold Tips ↗Sidewalk Shed Renewal Reports →CD-5 & Permit Expediting →
Service 04 · CD-5

What We Deliver for Your Scaffold

Façade restoration, Local Law 11 / FISP repairs and window work depend on suspended scaffolds that are designed right the first time. NYC requires suspended scaffolds to be designed by a Registered Design Professional, and installations using outrigger beams or C-hooks require a CD-5 application. Momentum prepares the sealed design, calculations and filing package so your rigger can mobilize safely and on schedule.

Suspended scaffold platforms on a brick and concrete high-rise facade during masonry repair
Suspended Scaffold · Façade Restoration
  • Sealed scaffold design drawings
  • Outrigger beam calculations
  • Parapet clamp stability reports
  • CD-5 / DOB NOW filing package
  • Installation & removal notifications
Request Scaffold Design
Code RequirementsAt a Glance
BC 3314.3.2

Suspended scaffolds shall be designed by a Registered Design Professional, with limited exceptions for small single-tier scaffolds.

CD-5

Suspended scaffold applications using outrigger beams or C-hooks are filed with the DOB Cranes & Derricks Unit.

BC 3314.4.1.5

DOB must be notified of suspended scaffold installation and removal — by the licensed rigger or the design professional who designed the scaffold.

Parapet Clamps

A stability report signed and sealed by a Registered Design Professional must be on site and available for DOB review.

BC 3314.10

Installation inspections; where the integrity of the support surface is in question, a NYS-licensed P.E. or R.A. must be consulted.

Summary for general information only. Requirements are confirmed for each project against the current NYC Construction Codes and DOB rules.
Service Area

Suspended Scaffold Design (CD-5) Across NYC & Northern NJ

FAQ

Suspended Scaffold Design (CD-5): Common Questions

When does a suspended scaffold need to be designed by an engineer?

Under BC 3314.3.2, suspended scaffolds must be designed by a Registered Design Professional, with limited exceptions for small single-tier scaffolds.

What is a CD-5?

A CD-5 is the DOB application filed with the Cranes & Derricks Unit for suspended scaffolds that use outrigger beams or C-hooks.

Do you provide parapet clamp stability reports?

Yes. Where parapet clamps are used, a stability report signed and sealed by a Registered Design Professional must be available on site, and we prepare these reports.

Ready to move your project forward?